Product Details:
Minimum Order Quantity | 1 Piece |
Weight (Kilogram) | 500 |
Power Supply (V per Hz) | 230V50HZ |
Response Time | 10 |
Product Type | Puc Machine |
Humidity (%) | 100 |
Display Type | LCD |
Model | AVG500 |
Condition | New |
Display (Inch) | 4 |
Power (Watt) | 50 |
Measurement Gas Pressure | 1BAR |
Application | VEHICLE POLLUTION TESTING |
Brand | Airvisor |
Color | BLUE |
Temperature (Degree Celsius) | 100 |
Air visor 4 gas analyser.
The AVG-500, 5 Gas Analyzer developed by AIRVISOR TECHNOLOGIES is best product in it’s class. Due to its latest technology and spares used for its development, it becomes a product which never been introduced in Indian market. Dual Head pump provides faster response time for gas sampling. While automatic drain facility ensures the vapor separation from the exhaust sample. Multi display pages offers user to switch between pre-configured measurement items on each page, it offers user to select either big font size display page or all gases in a single page, another page provided to have a look on Oil Temp, Corrected CO, AFR, PEF, RPM. AVG-500 is designed using “CAP3030 NDIR Gas Bench” manufactured by CAPELEC-France.
1. Scope
The AVG-500 is intended to use for measurement of emission gases i.e. Carbon Monoxide, Carbon Dioxide, Hydro-Carbons, Oxygen through tail pipe of internal combustion engines running on fossil fuels like Petrol / CNG / LPG. Proper filtration of exhaust sample is recommended during measurements.
2. Usage Conditions
The AVG-500 is designed to use within range of 160 volts to 250 volts AC at 50/60 Hz frequency. Using beyond these specifications may cause serious damage of power supply unit. To ensure prevention of electrical shocks, proper earth in power supply is required. The equipment is designed for indoor and outdoor usage keeping in mind that equipment should be used in a well ventilated and shaded place. Use of the equipment in rainy and misty conditions will require regular inspection of water separator unit to ensure proper drain of condensation. Due to sensitive parts used in this equipment, it is required to operate by a trained operator only. The equipment should be strictly opened / serviced by a qualified service engineer because it contains corrosive materials which may lead to serious injuries. The equipment must not be used with soiled or damaged filters which may cause dust contamination in sample line and lead to major break downs. Periodic maintenance of the equipment should be carried out in timely manners as specified in General Maintenance section.2. RS232 :Output for PC Connection
3. Printer :Output for Thermal Printer
4. Oil Temp: Connection of Oil Temperature Sensor
5. Tacho / Vibration : Input of RPM Measurement Device
6. Inductive RPM : Connection Port for Inductive RPM
7. Gas Inlet : Input Port for Exhaust Sample
8. Calibration : Input Port for Calibration Gas
9. Drain Out: Discharge of Water from Sample
10. Drain In: Input of Separated Water for pump
11. Gas Out :Discharge of Measured Sample
12. Water Separator :Device for Separation of Water from Sample Gas
Additional Information:
Product Details:
Brand | AIRVISOR |
Smoke Cell | 215 mm |
Printer | Thermal Printer |
Dimensions | L240xW215xH182 mm |
Weight | 6 kg |
Power Requirement | 140 to 260 Volts AC (50 Hz),65 Watts |
Measurement Range | 0 to 99.9 % |
RPM | 0 to 6000 rpm |
Oil Temperature | 0 to 150 Degree Celsius |
Accuracy | +/-00.5% |
Input Method | 6 Keys Membrane keyboard |
Warm Up Time | Less than equal 10 min |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Model | AVS100 |
Product Type | PUC MACHINE |
Usage/Application | VEHICLE PUC TESTING |
Model Number/Name | AIRVISOR |
Application | PUC TESTING |
Color | black |
Automation Grade | Automatic |
Display (Inch) | 2 |
Warm Up Time | 3MINUTES |
Display Type | LCD |
Weight (Kilogram) | 600 |
Power (Watt) | 100 |
Engine Rpm Battery Based | MAGNETIC |
Type | OPACITY METER |
Brand | AIRVISOR |
Diesel smoke meter model avs100 ( ARAI APPROVED)
We manufacture and export best in class diesel smoke meter as per indian Govt cmvr rules and it is ARAI approved . taking forward the make in India project this machine is indigenously made by our R & D department. It uses a gas chamber which measure the density of smoke in percentage and k value using best in class tachometer and oil temperature meter.
Portable Design.
our smoke meter can detect smoke reading within 7 minutes and it is approved by VAHAN4 regulations for ONLINE PUC UPGRADATION.
APPROVE AS PER OIML Class ''0'' Compliant
High Quality Indigenous Product
Battery / Vibration RPM Measurement
Specifications
Principal : Attenuation of Light Beam
Smoke Cell: 215 mm
Measurement Range HSU : 0 to 99.9 %
K : 0 to 15.0 m-1
Resolution HSU : 0.1 %
K : 0.01 m-1
RPM : Piezo Type (1 RPM), Battery / Vibration (10 RPM)
Oil Temperature : 1 Degree Celsius
RPM (Optional) Piezo : 0 to 6000 RPM Battery : 0 to 8000 RPM Magnetic : 0 to 6000 RPM
Oil Temp (Optional) 0 to 150 Degree Celsius
Accuracy HSU : +- 00.5% K : +- 0.1 m-1
Display 16X4 Liquid Crystal Display
Input Method 6 Keys Membrane keyboard
Warm Up Time ≤ 10 Minutes
Auto Zeroing ≤ 15 Seconds
Printer (Optional) Thermal Printer
Dimensions (L) 240 mm X (W) 215 mm X (H) 182 mm
Weight 6 Kilo Grams
Operating Temp. -5 Degree Celsius to 55 Degree Celsius
Power Requirement 140 to 260 Volts AC (50 Hz), 65 Watts
Standard Accessories Smoke Meter Unit, Power Cord, Communication Cable, Sampling Probe,Sampling Pipe, Remote Handheld Unit, PC Software, User Manual
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | PUC TESTIN |
Product Type | PUC |
Voltage | 230 |
Power Supply | SINGLE PHASE |
Features | ANALYSER |
Model Number/Name | AVG500 |
Application | PUC |
Engine Rpm Battery Based | MAGNETIC |
Automation Grade | Automatic |
Brand | Airvisor |
Exhaust gas analyser model AVG500
Petrol puc testing machine model avg500 by airvisor is arai approved pollution testing machine and also approved by VAHAN4 OF SURFACE MINISTRY BY INDIAN GOVT FOR TESTING VEHECLES PUC ONLINE ON PARIVAHN WEBSITE.
The gas analyser is upgadable to onlinepuc regulation of government of india.
This Puc machine is also upgradable to fifth gas that is nox.
This machine can be connected to either laptop or a pc.
Puc machine is made in india and made as per european standards providing best in class quality with zero maintenance.
thismachines can test pollution of all kindls of petrol cng or lpg driven vehicle along with it the machine can also test carbon diaoxide, hydrocarbon, lamda , air fuel ration and rpm in real time.
we have used caplec from france gas bench which is very sturdy in accuracy and performance.